Agenda Constructiilor
Joi, 02 Mai 2024
STIHL
Home - Stiri - English Section - ANALISYS: Sound insulation of the lift-and-slide door assemblies
ANALISYS: Sound insulation of the lift-and-slide door assemblies
English Section Publicat de Ovidiu Stefanescu 17 Feb 2015 15:12
Models of lift-and-slide doors are used to equip different types of buildings, acting as a communication interface between inside and outside and being included in the building enveloping system. Often, these solutions are used for reasons of architectural design, but there are more and more situations where such systems are chosen in order to optimize the internal areas by maximizing the effectiveness. Unlike traditional products ranging from windows and doors (operated tilt-turn) for the above mentioned solutions do not exist collections of values determined in advance on the indicators of sound insulation in accordance with DIN 4109. Also, the harmonized norm governing the production of windows / doors (EN 13451-1) does not offer further details, providing only those characteristic verification option based on tabulated values determined for sliding models. Another unacceptable limitation is that the maximum coefficient of acoustic protection (Rw) is only 30 dB. All this are reasons determining the experts to start a complex process of solving the problem. Measurements aimed at determining the acoustic protection achieved in the last twenty-five years in the IFT Rosenheim laboratory were compiled and the results of this integration process are described for the experts involved in the special windows and doors production. In total, over the mentioned period, there were conducted more than 200 independent tests, which were addressed to models made of plastic, wood or composite elements including metal profiles (especially aluminum with polyamide thermal barrier). Out of the total laboratory tests, 60 have targeted sliding assemblies (of which 59 were windows made of composite materials), and 144 have referred to the lift-sliding models (69 ensembles from PVC, wood or timber, 11 of aluminum, respectively 64 composite). The processes determining the degree of sound insulation were conducted in accordance with applicable standards governing the specific activity (currently EN ISO 10140, Parts 1-5), which impose the use of elements with areas larger than 6 square meters.
 
 
Agenda Investitiilor
ABONARE REVISTA (click aici):  PROIECTE | INVESTITII | REVISTE | INDEX COMPANII
DATE DE CONTACT: Agenda Constructiilor & Fereastra - Tel/Fax: 021-336.04.16, 031-401.63.88
 
ABONARE REVISTEhiltiSISECAMRAWLPLUGALLBIM
ROCKWOOL 196
Editia
MARTIE/APRILIE 2024!
- pe site -
Revista Agenda Constructiilor editia nr. 181 (Martie-Aprilie 2024)
 

Autentificare

romania fara hospice
GHID de INSTALARE
CONCEPT STRUCTURE
CDS
Acvatot 2019
concelex
rigips
quadratum
EDIT-Structural
strabag nivel 1
Ubitech
ERBASU CONSTRUCT
MAKITA
noark
theda mar
leviatan
ness project
siniat
viarom

Parteneri

HABITAT
top 500
AHK 2022
FPSC_2019
INNOCONSTRUCT2024
ef-de-n
top 500
econet
top 500
AICPS_30
ROGBC 2016

pereti cortina si tamplarie aluminiu exigeretamplarie aluminiu Termopan Salamander