Agenda Constructiilor
Sambata, 07 Iunie 2025
ABONARE REVISTE
Home - Stiri - English Section - ANALISYS: Sound insulation of the lift-and-slide door assemblies
ANALISYS: Sound insulation of the lift-and-slide door assemblies
English Section Publicat de Ovidiu Stefanescu 17 Feb 2015 15:12
Models of lift-and-slide doors are used to equip different types of buildings, acting as a communication interface between inside and outside and being included in the building enveloping system. Often, these solutions are used for reasons of architectural design, but there are more and more situations where such systems are chosen in order to optimize the internal areas by maximizing the effectiveness. Unlike traditional products ranging from windows and doors (operated tilt-turn) for the above mentioned solutions do not exist collections of values determined in advance on the indicators of sound insulation in accordance with DIN 4109. Also, the harmonized norm governing the production of windows / doors (EN 13451-1) does not offer further details, providing only those characteristic verification option based on tabulated values determined for sliding models. Another unacceptable limitation is that the maximum coefficient of acoustic protection (Rw) is only 30 dB. All this are reasons determining the experts to start a complex process of solving the problem. Measurements aimed at determining the acoustic protection achieved in the last twenty-five years in the IFT Rosenheim laboratory were compiled and the results of this integration process are described for the experts involved in the special windows and doors production. In total, over the mentioned period, there were conducted more than 200 independent tests, which were addressed to models made of plastic, wood or composite elements including metal profiles (especially aluminum with polyamide thermal barrier). Out of the total laboratory tests, 60 have targeted sliding assemblies (of which 59 were windows made of composite materials), and 144 have referred to the lift-sliding models (69 ensembles from PVC, wood or timber, 11 of aluminum, respectively 64 composite). The processes determining the degree of sound insulation were conducted in accordance with applicable standards governing the specific activity (currently EN ISO 10140, Parts 1-5), which impose the use of elements with areas larger than 6 square meters.
 
 
ALLBIMBIMTotalEnergieshilti
ROCKWOOL 196
Editia
MAI 2025!
- pe site -
Revista Agenda Constructiilor editia nr. 190 (Mai 2025)
 

Autentificare

Editia
MARTIE-APRILIE 2025!
- pe site -
Revista Agenda Constructiilor editia nr. 189 (Martie-Aprilie 2025)
 
romania fara hospice
GHID de INSTALARE
BogArt
quadratum
Arduro
leviatan
EURO BUILD
GEWISS
Acvatot 2019
SSAB
ERBASU CONSTRUCT
strabag nivel 1
SIGM
concelex
CONCEPT STRUCTURE
CDS
Daikin
noark
MAKITA
EDIT-Structural
MCA
theda mar
Eco Garden Construct
TECNIC
KADRA
AED
ELECTROGRUP
Ubitech

Parteneri

HABITAT
FPSC_2019
 

Tamplarie aluminiu Termopan Salamander Pereti cortină Tâmplărie din aluminiu urmarirea comportarii in timp a constructiilor