Agenda Constructiilor
Vineri, 09 Mai 2025
ABONARE REVISTE
Home - Stiri - English Section - ANALISYS: Sound insulation of the lift-and-slide door assemblies
ANALISYS: Sound insulation of the lift-and-slide door assemblies
English Section Publicat de Ovidiu Stefanescu 17 Feb 2015 15:12
Models of lift-and-slide doors are used to equip different types of buildings, acting as a communication interface between inside and outside and being included in the building enveloping system. Often, these solutions are used for reasons of architectural design, but there are more and more situations where such systems are chosen in order to optimize the internal areas by maximizing the effectiveness. Unlike traditional products ranging from windows and doors (operated tilt-turn) for the above mentioned solutions do not exist collections of values determined in advance on the indicators of sound insulation in accordance with DIN 4109. Also, the harmonized norm governing the production of windows / doors (EN 13451-1) does not offer further details, providing only those characteristic verification option based on tabulated values determined for sliding models. Another unacceptable limitation is that the maximum coefficient of acoustic protection (Rw) is only 30 dB. All this are reasons determining the experts to start a complex process of solving the problem. Measurements aimed at determining the acoustic protection achieved in the last twenty-five years in the IFT Rosenheim laboratory were compiled and the results of this integration process are described for the experts involved in the special windows and doors production. In total, over the mentioned period, there were conducted more than 200 independent tests, which were addressed to models made of plastic, wood or composite elements including metal profiles (especially aluminum with polyamide thermal barrier). Out of the total laboratory tests, 60 have targeted sliding assemblies (of which 59 were windows made of composite materials), and 144 have referred to the lift-sliding models (69 ensembles from PVC, wood or timber, 11 of aluminum, respectively 64 composite). The processes determining the degree of sound insulation were conducted in accordance with applicable standards governing the specific activity (currently EN ISO 10140, Parts 1-5), which impose the use of elements with areas larger than 6 square meters.
 
 
Agenda Investitiilor
ABONARE REVISTA (click aici):  PROIECTE | INVESTITII | REVISTE | INDEX COMPANII
DATE DE CONTACT: Agenda Constructiilor & Fereastra - Tel/Fax: 021-336.04.16, 031-401.63.88
 
TotalEnergieshiltiRAWLPLUGALLBIM
ROCKWOOL 196
Editia
MARTIE-APRILIE 2025!
- pe site -
Revista Agenda Constructiilor editia nr. 189 (Martie-Aprilie 2025)
 

Autentificare

romania fara hospice
GHID de INSTALARE
SSAB
Eco Garden Construct
AED
MAKITA
BogArt
SIGM
concelex
quadratum
GEWISS
TECNIC
CONCEPT STRUCTURE
CDS
KADRA
Daikin
theda mar
ERBASU CONSTRUCT
strabag nivel 1
MCA
Arduro
leviatan
ELECTROGRUP
EDIT-Structural
Acvatot 2019
noark
VEGO
EURO BUILD
Ubitech

Parteneri

HABITAT
FPSC_2019
inoconstruct

pereti cortinaTamplarie Aluminiu.ro Termopan Salamander
urmarirea comportarii in timp a constructiilor<